Test HV-fanout 04 
 
Measurement with 
Duration of test
1,0 kV
1 min / input pin
3,0 kV negative
1 min / input
Input
Input pin
Resistance
> 1x 1013 ohm
Leakage current
[nA]
A
 
1
2
3
4
5
6
7
8
 
 
OK
OK
OK
OK
OK
OK
OK
OK
 
< 1,0
B
 
1
2
3
4
5
6
7
8
 
 
OK
OK
OK
OK
OK
OK
OK
OK
 
< 1,0
C
 
1
2
3
4
5
6
7
8
 
 
OK
OK
OK
OK
OK
OK
OK
OK
 
< 1,0
 
Tests
Results
Mechanical test of SHV connectors 
 + HV connectors (ability to plug in/off)
OK
Check of ground connection of each SHV connector 
 + HV connectors   Resistance   < 1 x 10-2 ohm
OK
Check of central wire connection on each SHV connector 
+ HV connectors   Resistance   < 2 x 10-1 ohm
OK
 
Date: 4.December 1997                                                        Signature: Zdenek Kotek